JavaScript seems to be disabled in your browser. For the best experience on our site, be sure to turn on Javascript in your browser.
Customer Service: [email protected]
InverX20 Inverter Heat Pump
Introducing the impressive Fairland InverX20 Full-Inverter heat pump based on Fairland's original Full-Inverter technology. The heat pump features Fairland's self-developed control system, perfectly matching the inverter compressor and the extreme 3D heat-exchanging technology. This unique technology intelligently optimises the gas flow rate to maximise the COP performance.
Have you found a lower price or received a better quote? Click here to fill out the attached form, and we will strive to beat or match the price.
Please email or call 0333 900 4040 for price
Lead Time: Next Working Day
3D Heat Exchanging Tech:
Fairland has developed a new generation of 3D heat-exchanging technology that redefines titanium heat exchangers, increasing the exchanging area by 30% and improving efficiency by 30%.
3 Modes to Efficiently Control Consumption:
Features:
Model
X20-14
X20-18
X20-22
X20-26
X20-32
Advised pool volume (m3)
30~50
40~65
45~75
55~90
65~105
Working air temp (°C / °F F)
-20 ~43 / -4 ~109
Performance Condition: Air 26°C / 80°F F, Water 26°C / 80°F F, Humidity 80%
Heating capacity (kW) in Turbo mode
14.0
18.5
22.0
26.5
32.0
Heating capacity (kW) in Smart mode
12.0
15.4
18.0
22.5
27.5
COP
20.0~7.8
19.6~7.2
21~7.4
20.7~7.5
20.0~7.3
COP at 50% capacity
15.2
14.8
15.3
15.1
COP at 20% capacity
20.0
19.6
21.0
20.7
Performance Condition: Air 15°C / 59°F F, Water 26°C / 80°F F, Humidity 70%
9.2
12.5
18.2
22.3
7.5
10.4
15.0
8.1~5.4
8.2~5.1
9.0~5.4
9.5~5.5
8.3~5.4
7.3
7.6
8.0
8.1
8.2
9.0
9.5
8.3
Performance Condition: Air 7°C / 45 °F F, Water 26°C / 80°F F, Humidity 90%
7.4
10.5
11.8
15.5
17.8
7.1~4.6
7.0~4.4
7.4~4.5
7.3~4.7
Sound pressure at 1m dB(A)
37.8~45.9
41.5~47.3
41.9~49.5
39.7~49.8
42.1~50.3
Sound pressure of 50% capacity at 1m dB(A)
40.3
42.5
43.3
43.1
45.2
Sound pressure at 10m dB(A)
17.8~25.9
21.5~27.3
21.9~29.5
19.7~29.8
22.1~30.3
Power supply
230V /1 Ph / 50Hz
Rated input power (kW) at air 15°C / 59°F
0.19~1.7
0.25~2.45
0.27~2.74
0.32~3.31
0.46~4.1
Rated input current (A) at air 15°C / 59°F
0.83~7.39
1.09~10.65
1.17~11.9
1.39~14.4
2.01~17.8
Advised water flux (m³/h)
3~4
4~6
6.5~8.5
8~10
10~12
Water pipe in-out Spec (mm)
48.3
Net Dimension L × W × H (mm)
945×432×660
1045×432×660
1195×432×760
1072×536×956
1264×536×956
Net Weight (kg)
65
73
82
100
122
What Circuit Breaker is Required